Appraisal methods of “Anyun” berth lock
The product is developed and produced by our company, and obtained “New Practical Patent” and “Appearance Design Patent” awarded by the State Patent Bureau in 2003 and 2004 respectively. Any unit or individual’s making similar products shall be acts of infringement, and our company will safeguard its intellectual property right at all costs. Customers are advised to our company’s products to avoid being cheated and causing unnecessary economic losses and troubles.
1、Our company adopts imported outdoor powder coating. In appearance, they have high gloss degree, strong adhesion, and the color doesn’t fade easily; fake products have coarse paint coating, the paint comes off easily, and many inside wires are exposed to the outside.
2、Product specification: 640*158*80mm, the highest position: 300mm; fake products are longer and wider than our products, causing products to be not voltage-resistant and easy to be distorted.
3、All hardware parts are made by mould opening. Where night light “Exclusive Berth” words are affixed there is a groove of 320*32mm, and on the right where aluminum sign is affixed there is a groove of 70*35mm; fake products adopt section bar, the thickness is not enough, and there are no grooves.
4、Relevant packing arrangements: berth lock host, charger, two remote controls, four bulgy screws, rocking handle, and warranty card and the instructions (Chinese and English edition).
5、Storage battery is 12V, 8AH, dedicated battery of remote control berth lock, characterized by low self-discharge capacity, long waiting time and complete seal; fake products adopt 12V, 7AH storage battery common in the market, with obvious welding joint, waterproof glue easily comes off, causing shirt circuit of battery and severe fire or explosion.
6、The bracket part is also made by mould opening, and it adopts cold rolled sheet 3.0mm in thickness; fake products adopt section bar 0.8-1.2mm in thickness, causing berth lock easy to shake, not firm and easy to be distorted.
7、Control panels adopt imported electronic components, chips are made in Japan with high stability, static electricity is controlled below 1.5mA, and when charged one time they can be used for more than 4 months; fake products adopt domestic electronic components, electric current is generally more than 4mA, and when charged one time they can be used for 2 month at most.
8、Our company adopts DC connector plugs, charging is convenient, no need to consider positive and negative electrodes; fake products adopt aviation plugs, charging is extremely inconvenient, easy to connect positive and negative electrodes incorrectly, causing charger and storage battery to be burnt.
Troubleshootings for automatic parking spot lock controller
|
Order No. |
Fault |
Reason |
Debugging |
|
1 |
No respond to remote control |
Remote control’s indicator light is not on |
Battery of remote control is dead |
Replace battery of remote control |
|
Remote control’s indicator is on
|
storage battery is dead or plug is loose |
1. refresh battery, make the plug connected |
|
1. limit switch’s shrapnel doesn’t flick |
2. poke shrapnel |
|
2. supporter is distorted |
3. replace supporter |
|
3. something wrong with control panel |
4. replace control panel |
|
4. something wrong with electric machine |
5. replace electric machine |
|
2 |
Not reaching the designated position when going up or down |
1. supporter is distorted
|
1. replace supporter
|
|
2. foreign object inside base hinders supporter’s movement
|
2. remove foreign object
|
|
3 |
Giving an alarm after going down
|
Shrapnel of lower limit switch is distorted
|
Adjust shrapnel
|
|
|
|
Going up to the designated position |
1. Shrapnel of upper limit switch is distorted
|
2. adjust shrapnel
|
|
5 |
Storage battery cannot be regenerated
|
1. storage battery doesn’t work
|
1. replace battery charger
|
|
2. something wrong with storage battery
|
2. replace storage battery
|
|
6 |
External power source
No respond to remote control
|
One or non-continuous multi- ones
|
1. refer to Fault 1
|
1. refer to Fault 1
|
|
2. incoming line’s joint of control is broken
|
2. connect joint and make it waterproof |
|
Continuous multi-ones
连续多台 |
1. incoming line and lead line of the first one with fault and next to power end is broken
|
1. connect joint and make it waterproof
|
|
2. line of electricity transmission backward of the normal one next to the one with fault is broken
|
2. connect joint and make it waterproof
|
|
None of the controls shared by the same switch power supply move
|
1. electricity failure
|
1. first use swing arm, use it in a normal way after electricity comes |
|
2. switch power supply’ outgoing line is connected reversely
|
2. connect it correctly
|
|
3. switching power supply is damaged
|
3. replace switching power supply
|